Commercial Pool Heaters
42
OPERATION
Continued
HOT SURFACE IGNITION SYSTEM
Hot Surface Igniter and Ignition Control
Module
This unit has one ignition module and one hot surface igniter.
Figure 47 – Hot Surface Igniter
Figure 48 – Hot Surface Ignition Control Module
Hot Surface Ignition Control Module
Ignition Module Lockout Functions
The ignition module may lockout in either a hard-lockout
condition, requiring pushing of the reset button to recycle the
control, or a soft-lockout condition which may recycle after an
approximate five-minute waiting period. This soft-lockout
condition is intended to allow self-correcting faults to correct
themselves and permit normal operation. A typical hard-
lockout fault is a flame failure condition. An ignition module
that is in a hard-lockout condition may only be reset by
pushing the reset button for the ignition control. The reset
button is located on the front of the control panel. Upon a
flame failure, the reset button is only active after the control
module has completed its post-purge cycle. Turning main
power “OFF” and then “ON” or cycling the thermostat will not
reset a hard-lockout condition. Wait five seconds after turning
on the main power before pushing the reset button when the
ignition module is in a hard lockout.
The ignition module will go into a soft lockout in conditions of
low air, low voltage or low hot surface igniter current. A soft-
lockout condition will operate the combustion air fans for the
post purge cycle and then the ignition module will pause for
approximately five minutes. At the end of this timed pause, the
ignition module will attempt a new trial for ignition sequence.
If the soft-lockout fault condition has subsided or has been
corrected at the end of the timed pause, main burner ignition
should be achieved with the resumption of the normal trial for
ignition sequence. If the control sensed fault is not corrected,
the ignition module will continue in the soft-lockout condition.
If the thermostat opens during the soft-lockout period, the
ignition module will exit soft lockout and wait for a new call
for heat from the thermostat. A soft-lockout condition may
also be reset by manually cycling the thermostat or turning the
main power switch “OFF” and then “ON” after the control
sensed fault has been corrected.
Diagnostic Status Indication
The ignition module has an LED which indicates the status of
the safety circuits. A remote Ignition Module Status indicating
light is wired from the ignition module Status LED and
mounted on the front control panel. The flashing operation of
this light/LED indicates the diagnostic status of the ignition
control module. The status LED, mounted on the ignition
module, flashes a code sequence from the Ignition Module to
indicate the status of the ignition process. See TABLE– N, on
page 43 for the flashing diagnostic status codes as signaled by
the ignition module.
CAUTION: The igniter is extremely fragile, be
very careful when removing. A faulty or damaged
hot surface igniter MUST BE replaced with a
Lochinvar PLT3400 igniter. DO NOT use general
purpose field replacement igniters.